Fike fm 200 operation manual

A clean agent fire suppression valve controls the pressure within. Fm200 fire suppression system design, installation, operation and maintenance manual part number. Procedure for removing fike gca gas cartridge actuator. The gca is designed to operate in all fike clean agent system containers with 1 and 2 12 valves and also containers with 3 valves with single disc packs. This manual will assist the systems designer to properly design a fike micromist fire suppression. The clean agent fire extinguishing system shall consist of fm 200, agent cylinders, 1800. The extinguishing performance of fm200 appears to be not so quick as btm. The clean agent fire extinguishing system shall consist of fm200, agent cylinders, 1800. This detection system is used to actuate a single, fixed fire suppression or alarm system based on inputs received from fire detection devices. Fm 200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements. Fike safety technology ltd, do not call the fike safety technology technical support 31 springvale ind est, department unless your distributor has first given their advice and cwmbran, uk. The physical and chemical properties of fm200 are not the same as btm. Fm200 total flooding fire suppression system general the fm200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing systems.

Fike fm 200 clean agent fire suppression system with the shp pro control panel fm 200 system w shp pro specification page 3 of 8 pn. Design, installation maintenance manualfm200fike free download as pdf. Fm200 fire suppression system costeffective protection. Operation of manual discharge station shall duplicate the crosszones sequence description above, except that timedelay shall be bypassed.

Fm200 clean agent systems associated fire protection. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection. Design, installation maintenance manualfm200fike 5143vky9x9nj. Two 2 copies of the kidde fire systems design, installation, operation and maintenance manual for the ads clean agent fire extinguishing system employing fm 200 shall be submitted after complete installation. The term novec 1230 employed throughout this manual refers to the extinguishing agent dodecafluoro. Learn how the the fm200 clean agent fire protection system hfc227ea leaves.

Upon activation, fm200 is discharged as a liquid through the nozzles to a predetermined concentration, usually 7%. Two 2 copies of the kidde fire systems design, installation, operation and maintenance manual for the ads clean agent fire extinguishing system employing fm200 shall be submitted after complete installation. Our clean agent fire protection system, using dupont fm200 as thefm200 fe227ea heptafluoropropane cf3chfch3extinguishing agent, leaves no residue and doesnt require. Cheetah xi intelligent fire suppression control system by fike. The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. In certain marine applications, it can be activated by a fusible link. Refer to fike hfc227ea fm200 instruction manual for liquid level indicator lli, pn 06107. In applications where space is at a premium, fm200 fire suppression systems are the superior choice. This technical manual provides the necessary information for the design, installation, operation and maintenance of a chemetron fm200 sigma series engineered system. Fm200 fire suppression system costeffective protection for. Fm200 clean agent fire suppression system physical properties chemical name heptafluoropropane cf3chfcf3 molecular weight 170.

This device is designed to operate by two methods of actuation. Jenis control accessories fike fm200 alat pemadam kebakaran. For ecaro25 systems, the maximum operating temperature is 120f 49c. Firetrace fm200 automatic indirect fire suppression units are to be designed, installed, inspected, tested, maintained, and recharged by qualified trained personnel in accordance with the following. The chemical is 1,1,1,2,3,3,3heptafluoropropane or hfc227ea, liquefied compressed gas. Level readout is obtained by simply removing the protective cap and pulling out a calibrated tape until magnetic interlock with the float. Conventional fire alarm and suppression system fike. Procedure for removing fike gca gas cartridge actuator devices from fike system bottles. The control unit shall be approved by underwriters laboratories, inc. The detection circuits can be configured using cross, counting, independent or. The primary extinguishing mechanism of fm200 is heat absorption, with a secondary chemical contribution from the thermal decomposition of fm200 in the flame. Factory mutual fm fm200 systems are manufactured in strict accordance with the internationally recognised quality assurance standard, bs en is0 9000 and approved to iso 9001 fm200 extinguishing system units are to be designed, installed, inspected, maintained, tested and recharged. When fires are extinguished in the early stages loss of life is minimal since 93% of all firerelated deaths occur once the fire has progressed beyond the early stages. Design, installation maintenance manualfm200fike gases.

Components provided by the manufacturer shall carry a warranty of thirtysix. A the system shall be a total flood fm 200 suppression system supplied by. The panel shall accept input from the following types of equipment used to make up the system. Jul 31, 2014 procedure for removing fike gca gas cartridge actuator devices from fike system bottles. Nama buku manual merk document library 1 kidde fm200 ecs series engineered kiddefm200 download 2 kidde fm200 marine ecs series engineered kiddefm200 download 3 kidde novec1230 ecs series engineered kiddenovec download 4 kidde ig55. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Ecs series engineered fire suppression system design. Automatic fire suppression systems control and extinguish fires without human intervention. Refer to fike hfc227ea fm 200 instruction manual for liquid level indicator lli, pn 06107. A seperate entrance or gate must be installed for pedestrian use see page viii. Cheetah xi intelligent fire suppression control system fike.

Rotarex north america firedetec indirect low pressure ilp dupont fm200 preengineered fire suppression systems featuring linear pneumatic tubing design, installation, and maintenance manual, pn 027650004 date 12 limitations or exceptions to approval. Fm200 fire suppressant can be safely used where people are present. Most common metals, such as aluminum, brass, steel, cast iron, lead, stainless steel, and copper, as well as rubber, plastic, and electronic components, are. The fm200 system is most effective when used with a detection system to introduce the clean agent rapidly. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Fike clean agent systems with impulse technology fike is known worldwide as an innovator in fire suppression equipment and fire protection technology. Jenis control accessories fike fm200 berikut tipe dengan kodenya perlengkapan pemadam api fike fm200. Standard operation of the valve is accomplished by a gas cartridge actuator. Sr200hfc227ea engineering manual sri issued sept 24, 2010, rev. The fm 200 system is most effective when used with a detection system to introduce the clean agent rapidly. About this manual this manual is a comprehensive guide that contains all the information necessary to design, install and maintain the fm 200 engineered extinguishing system however the manual does not address information relating to fire.

Impulse technology with over 60 years experience, fike is known. The system can be activated by smoke, infrared, or ultraviolet detectors or manual pull stations. Review the operation of the system to become familiar with its safety features. Fikes clean agent system with fm200 also known as hfc227ea, uses fikes patented rupture disc valve design offering additional. Hello guys learn fm 200 fire suppression release system wiring and operation.

Introducing the new fike impulse valve used with fike. And it discharges in 10 seconds or less, extinguishing a fire quickly and. The atmospheric lifetime of fm200 has been determined to be 36. About this manual this manual is intended to be a complete reference for the installation, operation, and service of the fike single hazard panel professional shp rpro fire alarmsuppression control system. Fm 200 fire suppression release system wiring and operation. Acoma drive, suite 106 scottsdale, az 85260 usa telephone. Operation of a manual device shall duplicate the sequence description above.

Fike clean agent containers have passed extensive testing by factory mutual and underwriters laboratory and are used in installations where 3 to 1045 pounds 2. Nama buku manual merk document library 1 kidde fm 200 ecs series engineered kiddefm200 download 2 kidde fm 200 marine ecs series engineered kiddefm200 download 3 kidde novec1230 ecs series engineered kiddenovec download 4 kidde ig55 argonite ecs series engineered kidde ig55 download 5. The system is designed and installed in accordance. And as a result of fikes advanced rupture disc technology, there is less agent loss. Fm200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements. A the system shall be a total flood fm200 suppression system supplied by. Fike liquid level indicator for fm200 clean agent systems fm200 is also known by its ashrae designation hfc227ea description the fike 7053 series liquid level indicator is a simple manually operated device which provides a means to determine the clean agent liquid level in vertically mounted agent storage containers.

Operation of manual discharge station shall duplicate the crosszones sequence description above, except that. Now, fike expands its clean agent offering with the addition of. Examples of automatic systems include fire sprinkler system, gaseous fire suppression, and condensed aerosol fire suppression. Understand how to disconnect the opener for manual gate operations see page iii. Fm200 and ecaro25 software packages have been updated to. Read pdf fike cheetah fire panel manual fike cheetah fire panel manual fire alarm control panel fike cheetah xi ground fault testing and diagnostic facp. Electric manual actuation impulse valve operator ivo for detailed. Maintenance manual for the clean agent fire extinguishing system employing fm200 shall be submitted after complete installation. The fm200 agent is stored in cylinders as a liquid and pressurized with nitrogen, saving huge amounts of storage space. Maintenance manual for the clean agent fire extinguishing system employing fm 200 shall be submitted after complete installation. Cheetah xi intelligent fire suppression control system is the ideal choice for your next installation of fire alarm, clean agent fire suppression, carbon dioxide suppression, watermist andor sprinklerpreaction sprinkler systems. Apr 23, 2018 hello guys learn fm 200 fire suppression release system wiring and operation. Manual or automatic actuators are available for release of the agent into the hazard area.

Fm 200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. Fike corporation 704 south 10th street blue springs, mo. The system shall be capable of being actuated by manual discharge stations located at each fire exit. This gate opener is intended for vehicular gates only. Fm200 fe227ea heptafluoropropane cf3chfch3 for speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. Fm200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. Operation a magnet equipped float moves with the liquid level along the unit stem. This is a single volume technical manual arra nged in 6 sections, followed by an appendix.

As with previous fike systems, the impulse valve technology continues to. The manual release switch is a dual actuation device which provides a means of manually discharging the automatic fire extinguishing system when used in conjunction with the fike control panel. That translates into less runoff, less damage and easy cleanup. Fm200 fire suppressant hfc227ea can be safely used where people are present.

136 513 366 1318 45 1511 1183 584 1279 223 111 135 132 1107 1044 647 1517 645 164 1067 630 1397 583 1073 1510 1234 788 965 1003 41 1280 911 814 1465 958